FM90
- Field Control® Fresh Mist Central System Humidifier
Freshmist 90
Owners Manual
Humidistat- Wall Mount
Wall mount
- Remove knob and cover from humidistat.
To remove cover, place screwdriver blade in slot at side of humidistat
and twist.
- Convert humidistat for wall mounting by removing control
unit from
back plate. Reassemble control unit to back plate as illustrated in (Fig.
22) with spacers to rear and shaft forward. Remove electrical disconnect
by cutting
the (2)
wires. Strip ends 1/2" for splicing to wall wire.

NOTE: Shaft extension is
not required for wall mounting.
- Select a location on a convenient
inside wall, usually beside your furnace thermostat.
- Run low voltage
wire through
the wall. Exit hole must be within the lower back plate opening. (Purchase
additional wire as required.)
- Connect low voltage wires from wall
to previously cut leads
on humidistat by stripping ends and using wire nuts (not provided).
Position and fasten humidistat to wall with 4 Screws provided. install
cover by
snapping onto back plate.
Press knob onto humidistat shaft. Make sure 1/8" air space is maintained
between wall and back plate to allow air circulation and humidity sensing.
- Connect
wiring (Fig. 23). Remove electrical disconnect by cutting wires on
harness, strip ends and splice to low voltage wire from wall humidistat
using wire
nuts. (Wire
nuts not provided.) Plug 24 VAC transformer into 120 VAC outlet.
Do not use existing transformer on furnace.
|
|
|