FM90
- Field Control® Fresh Mist Central System Humidifier
Freshmist 90
Owners Manual
Disassembly & Conversion
Disassembly
- Remove front cover. Lift top cover to lock position.
- Pull pivot pin and remove float assembly from valve.
- Lift out media
wheel.
- Remove water reservoir.
Conversion
- (if required - see "inspection" )
- Pull
motor bracket and wire bearing support to
remove from lances (Fig. 5).
- Install motor bracket on left side. Make sure bracket is
firmly seated (Fig. 6).

- Install wire support and nylon bearing in lances on right
side. Be sure groove in nylon bearing is toward inside
of humidifier. Bend
that
portion
of the wire
support leg extending below the lance, outward, to lock
support in lances (Fig. 7)
- After conversion, unit should look like (Fig. 8).
|
|
|