Disassembly & ConversionDisassembly
- Remove front cover. Lift top cover to lock position.
- Pull pivot pin and remove float assembly from valve.
- Lift out media wheel.
- Remove water reservoir.
Conversion
- (if required - see "inspection" )
- Pull motor bracket and wire bearing support to remove from lances (Fig. 5).
![]()
- Install motor bracket on left side. Make sure bracket is firmly seated (Fig. 6).
- Install wire support and nylon bearing in lances on right side. Be sure groove in nylon bearing is toward inside of humidifier. Bend that portion of the wire support leg extending below the lance, outward, to lock support in lances (Fig. 7)
![]()
- After conversion, unit should look like (Fig. 8).
![]()
<- Inspection