303.14701
- Sears/ Kenmore Central Humidifier
303.14701
Owners Manual
Service Hints
Service hints
Frequently what seems to be a major problem can be solved very easily. Listed
below are the common concerns with any humidifier.
Check the simple things first. Remove the front panel and see if there is
a crusty, white lime build up on the media pad. The lime build up won't hurt
the humidifier, but will reduce it's output. Low output might just mean your
humidifier needs cleaning.
CONDITION |
WHAT TO CHECK |
WHAT TO DO |
| To little Humidity |
- Check for obvious problems.
- Humidistat setting
- Water to unit
- Excessive air loss in house
- Is damper open?
|
-
- Replace media pad.
- Inspect main fuse or circuit breaker.
- Check to see if solenoid is operating.
- Humidistat setting is too low, turn knob clockwise to increase humidity.
- Check distribution pad set and clean or replace if dirty or clogged.
- Set for proper outdoor temperature - lowest 24-hour temperature.
- Turn saddle valve and check for possible obstruction in water line.
Is water supply connected? Check solenoid water filter and replace inlet
fitting filter/ orifice assembly if clogged.
- Close fireplace damper, seal around doors and windows.
- Slide damper out for winter operation.
|
| Too much Humidity |
- Humidistat setting.
- Other humidification sources.
|
- Turn knob counter clockwise to decrease humidity.
- May be a temporary condition caused by moisture from laundering, bathing,
cooking etc.
|
| Humidifier Making Noise |
- Mounting or plenum.
- Water pressure.
|
- Tighten all fasteners.
- A slight sound is normal as water enters humidifier.
|