Hunter Fan Company Integrated Remote Control Instruction SupplementSetting The Code When two or more fans are located near each other, you may desire to have each of them set to a different code, so that the operation of one fan will not affect another. This is accomplished by changing the position of any one or more of a group of 3 jumpers grouped together in the transmitter. The receiver located in the switch housing has the same set of 3 jumpers which must also be changed to match the transmitter settings. These jumpers are very small and can best be operated by using a small pair of pliers or tweezers. In the transmitter, the jumpers are readily accessible from the battery compartment. The switches in the receiver are located at the bottom of the receiver device in the switch housing. See Figures 1 and 2. To set the jumpers in the receiver, remove the receiver from the switch housing and set the jumpers in the same positions as the jumpers in the transmitter. See Figure 2. Replace the receiver, making sure the mounting holes at the top of the switch housing line up with the matching slots in the top of the receiver.
|
|
|||||||||||||||||||||||||||||||||||||