Home > Help Center > Ceiling Fan Information > Manuals > Installation for Remote All-Fan™ Fan and Light Control > Troubleshooting  

All-FanT 2-Wire Fan & Light Control Model 27186

Troubleshooting

Symptom Possible Causes Solution
1. No functions operate.
  1. Main Power not restored.
  2. Fan pull chain not set to High.
  3. Light pull chain not set to ON.
  4. Receiver wiring incorrect.
  5. Transmitter and receiver dip switches do not match.
  6. Battery too weak.
  1. Replace fuse.Turn ON circuit breaker. Turn ON wall switch.
  2. Turn OFF power at wall switch or main electric panel. Set fan to High speed.
  3. Set light kit to ON.
  4. Verify wiring connections.
  5. Set transmitter and receiver to same dip switch setting.
  6. Replace with new, alkaline battery.
2. Operates only at close range.
  1. Signal blocked from reaching receiver.
  2. Battery too weak.
  1. Extend antenna into ceiling box, or move it for better reception.
  2. Replace with new, alkaline battery.
3. Inconsistent operation.
  1. Signal partially blocked from reaching receiver.
  2. RF interference.
  3. Continuing RF interference.
  1. Extend antenna into ceiling box, or move it for better reception.
  2. Turn OFF wall switch for 5 seconds, then turn back ON.
  3. Change dip switch settings to a different code in both Transmitter and Receiver.