Enviracaire®
Portable Air Cleaner
READ AND SAVE THESE INSTRUCTIONS
For Model 16100 Series Air Cleaner
The Science of Clean Air®
Important Safety Instructions
PLEASE READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE
USING THIS AIR CLEANER.
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire, electric shock and
injury to persons including the following:
1. |
Read all instructions before operating
the air cleaner. |
2. |
Place air cleaner where it is not
easily knocked over by persons in the household. |
3. |
Always turn the air cleaner to the OFF
( ) position and unplug from the wall outlet when not in use. |
4. |
To disconnect the air cleaner, first
turn speed control to OFF (
) position, grip the plug and pull it from the outlet. Never pull by
the cord. |
5. |
Do not use any product with a damaged
cord or plug or if product malfunctions, is dropped or damaged in any
manner. Keep the cord away from heated surfaces. |
6. |
Do not use air cleaner outdoors. |
7. |
Never use air cleaner unless it
is fully assembled. |
8. |
Do not run power cord under carpets,
and do not cover with throw rugs. Arrange cord such that it will not
be tripped over. |
9. |
Do not use air cleaner where combustible
gases or vapors are present. |
10. |
Do not expose the air cleaner to
rain, or use near water, in a bathroom, laundry area or other damp location. |
11. |
The air cleaner must be used in
its upright position. |
12. |
Do not allow foreign objects to
enter ventilation or exhaust opening as this may cause electric shock
or damage to the air cleaner. Do not block air outlets or intakes. |
13. |
Locate air cleaner near power outlet
and avoid using an extension cord. |
14. |
This appliance has a polarized plug
(one blade is wider than the other). To reduce risk of shock, this plug
is intended to fit only one way in a polarized outlet. If the plug does
not fit fully in the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. DO NOT attempt
to defeat this safety feature. |
15. |
A loose fit between the plug and
the AC outlet (receptacle) may cause overheating and a distortion of
the plug. Contact a qualified electrician to replace loose or worn outlet. |
16. |
Do not sit, stand or place heavy
objects on the air cleaner. |
17. |
Disconnect power supply before servicing. |
WARNING: To reduce risk of fire or electric shock,
do not use this air cleaner with any solid-state speed control device.
Congratulations
You now own a quality portable air cleaner that has
been engineered and crafted for your satisfaction.
Our Consumer Relations representatives will be pleased
to help with any questions or concerns you may have about your air cleaner.
Please call our Consumer Relations Dept. at (800) 332-1110 for assistance
or email us at service@honeywell.com.
For Best Performance
We recommend that you operate your air cleaner 24
hours a day because indoor air can be quickly contaminated by activity in
a room, infiltration of outside air and from other sources of contamination.
While all the air in a room will not be processed by the air cleaner, the
more air circulated
through the filter, the more filtered air returned to the room. Portable
air cleaners will be much more effective in rooms where
all doors and windows are closed.
Place the air cleaner on a flat, level unobstructed
surface. For best performance the air outlet slot should not be blocked for
at least 3 feet (1 meter) in all directions.
NOTE: Due to the large volume of air drawn towards
the air cleaner, surrounding areas should be cleaned and/or vacuumed frequently
to prevent buildup. If the unit is placed on a light colored carpeting, a
small mat or rug should be used to ease cleaning and prevent any permanent
staining of carpeting. This is particularly important in homes with heavy
contamination from smoking or fireplaces.
Operation
The Honeywell 16100 Series air cleaner is a three
speed air cleaner operated by moving the speed control knob on the top panel
from the OFF ( ) position to the HIGH (III) position. Allow the unit to operate
for a few minutes at HIGH speed, then leave the control knob in the HIGH
position for faster, more powerful room cleaning or move the knob to the
lower setting (I) for quieter operation.
Speed levels (
-Off, III-HIGH, II-MED, I-LOW) are
molded in on the Speed Control/ Power Switch. The speed level indicator is
a molded line to the right of the speed control dial.
Replacement Filter
Model Series |
Odor-Lock Filter |
HEPA Filter |
16100 |
16800 |
16900 |
Replacement filters may be purchased from the retail
store or ordered from the dealer where you purchased the product. If you
cannot locate one, please call our Consumer Relations Dept. at (800) 332-1110,
email us at service@honeywell.com or visit our website at www.honeywell.com/yourhome.
Filter Replacement
NOTE: Filters are not washable and washing will damage
the filter
The Odor-Lock filter captures lint and other
large particles, helps protect the HEPA filter and helps reduce common household
odors. The Odor-Lock filter should be replaced at least every 3-6 months.
You may need to replace the Odor-Lock filter more often if the unit
is used in a smoking environment or if unpleasant odors persist.
The HEPA filter should remain effective for 1-3 years,
depending upon the environment in which the air cleaner is operating.
Our recommendations regarding filter replacement
are intended as guidelines only. Life expectancy of any filter media is dependent
on the concentration of the contaminants to which the system is exposed.
If there are sources of large amounts of contaminant generation (such as
dust from woodworking
or heavy smoking) the useful life of the filter media in your air cleaner
may be reduced.
CAUTION: TURN OFF THE AIR CLEANER AND DISCONNECT
FROM POWER SUPPLY BEFORE SERVICING
The only
two parts requiring any service are the Odor-Lock filter and the
HEPA filter. No tools are needed to change either filter. Change filters
as described here.
Step 1: Turn the Air Cleaner OFF
( ) and unplug from
the power supply.
Step 2: To open back grille, place your fingers on
the two tab indentations at the top of the unit just behind the calendar
wheel window area and gently push down and release the grille (Fig. 1). Completely
remove back grille from unit.
Step 3: Remove HEPA and Odor-Lock filter assembly
from the unit. Step 4: Remove the Odor-Lock filter from the HEPA filter
(Fig. 2). Step 5: Replace the filter(s) as needed, and discard used filter(s).
Step 6: Attach the Odor-Lock filter to the
HEPA filter using the fasteners that are pre-attached to the HEPA filter.
NOTE: When placing
the filter assembly back in the unit, make sure that the surface of the HEPA
filter that contains the foam sealant material is against the plastic divide
(Fig. 3, Fig. 4).
Step 7: Before reattaching the back air cleaner grille,
set appropriate filter change calendar(s) ahead according to the schedule
provided (Fig. 4).
Step 8: To reattach the back air cleaner grille,
insert the tabs on the bottom of the back grille into slots on the bottom
of the unit base. Next, insert the side tabs on the back grille with the
slots on the side of the unit. Then, push down firmly on top tabs, insert
and lock in place.
Step 9: Plug into a wall outlet.
Filter Replacement Reminders
Filter change schedule (depending upon use and conditions):
- Odor-Lock filter:
Replace every 3-6 months depending on use
- HEPA filter: Replace every 1-3 years depending
on use
Upon start
up of your Air Cleaner and every Odor-Lock filter
replacement, roll the Monthly Filter Change
Calendar ahead 3-6 months to indicate when filter replacement is necessary.
Upon start up of your Air Cleaner and upon every
HEPA filter replacement, roll the HEPA Filter Change Calendar ahead 1 to
3 years to indicate when filter replacement is necessary.
NOTE: Changing the
Filter Replacement Reminder wheels can only be accomplished by removing the
back grille from the front housing. The filter replacement month and year
are displayed through the two windows on the top of the control panel.
Troubleshooting
- Start on HIGH (III) for a few minutes, then adjust
to desired speed.
- This product
may emit a new smell which
will disappear over a relatively short period of operation.
- Check to make sure that the power cord is correctly
connected to the outlet.
- Test that the outlet is functioning properly by
using another appliance or lamp.
- Check the fuse or circuit breaker. The outlet may
be overloaded if other appliances are also in use. Determine and correct
the cause of the overload.
- Whenever the air resistance of the HEPA filter
becomes excessive due to the amount of contaminants it has captured, the
air volume output will begin to decrease and the sound level of the air
cleaner will increase. A completely blocked filter will cause a loud rumbling
sound because no air is getting through.
- If none of the above procedures restore operation,
return your unit to the store. If the store's return policy does not allow
the return, return the complete unit per the instructions in the warranty
section of this owner's manual. Do not attempt to repair the unit yourself
as it may cause injury, and the warranty does not cover damage resulting
from unauthorized attempts to repair or from any use not in accordance
with this manual.
Storage
If you store your Honeywell HEPA
air cleaner for more than 30 days, we recommend:
- Removing both
the primary HEPA filter and the Odor-Lock filter
from the unit.
- Discarding
the Odor-Lock filter.
- Wrapping the HEPA filter in an air-tight plastic
bag or plastic wrap. Be sure that the filter is totally sealed.
To restore
the air cleaner to service, unwrap the HEPA filter, install a new Odor-Lock filter, and reinstall both filters
in the air cleaner. See Filter Replacement section for proper
installation.
Three Year Limited Warranty
Honeywell
enviracaire® HEPA
Air Cleaner
Model No. Series 16100
This product has been engineered and crafted with
great care for your satisfaction. Be sure
to fill out and return the enclosed card within 10 days of purchase.
A. This limited warranty
applies to repair or replacement of product found to be defective in material
or workmanship within 3 years of the date of purchase. This warranty does
not apply to damage resulting from commercial, abusive, unreasonable use
or supplemental damage. Defects that are the result of normal wear and tear
will not be considered manufacturing defects under this warranty.
HONEYWELL IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY, INCLUDING MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, ON THIS PRODUCT IS LIMITED IN DURATION
TO THE DURATION OF THIS LIMITED WARRANTY. Some regions do not allow the exclusion
or limitation of incidental or consequential damages or limitations on how
long an implied warranty lasts, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal rights, and you
also may have other rights which vary from region to region. This
warranty applies only to the original Purchaser of this product.
B. At its option,
Honeywell will repair or replace this product if it is found to be defective
in material or workmanship within the limited warranty period. Defective
product should be returned to the place of purchase in accordance with store
policy or to Honeywell.
C. This warranty does
not cover damage resulting from unauthorized attempts to repair or from any
use not in accordance with this manual.
D. This
warranty DOES
NOT cover the Odor-Lock filter or HEPA
filter except for material or workmanship defects.
E. Return defective
product to the following address with a brief description of the problem.
Include proof-of-purchase and a U.S. $10.00 / Canadian $15.00 check or money
order for handling, return packing and shipping charges. Please include your
name, address and daytime phone number. You must prepay shipping charges.
Mark carton Attention Returns Department Ship
to:
In USA:
Honeywell Consumer Products
Returns Department
4755
Southpoint Drive
Memphis, TN 38118
U.S.A.
In Canada:
Honeywell
Consumer
Products
Canada
510 Bronte St.
South
Milton, Ontario Canada L9T 2X6
If you experience
a problem with your air cleaner, please see owner's guide for instructions.
Please do not attempt to repair the air cleaner yourself. Doing so may void
the warranty and could cause damage or personal injury. If the problem still
persists, please call:
Honeywell
Consumer Relations Dept.
Toll Free 1-800-332-1110.
Mail Questions or Comments to:
Honeywell
Consumer Relations Dept.
250 Turnpike Road
Southborough,
MA 01772, U.S.A.
or email us at: service@honeywell.com
Visit our
website at www.honeywell.com/yourhome
© 2000
Honeywell. All Rights Reserved. AC7009.00 035-00404-000
Rev 0
|